About 705,000 results
Open links in new tab
  1. Nozzle Pro and double fillet weld | Eng-Tips

    Mar 10, 2018 · Is it possible to calculate a nozzle with double fillet weld (without full penetration) by Nozzle Pro? I have a problem with it.

  2. Symbol for fillet weld with no filler? | Eng-Tips

    Jan 25, 2022 · It is currently called out as a fillet weld with 50% penetration, as they have trouble controlling distortion if they penetrate all the way through the tube wall. A fillet weld does not seem …

  3. What is a full strength penetration weld? | Eng-Tips

    Jan 23, 2007 · Doesn't full penetration refer to a weld the full depth of the material being welded independant of strength? My interpretation is penetration is the distance your weld extends below the …

  4. Reinforcement around Slab Openings | Eng-Tips

    Nov 17, 2006 · Article 13.4.2 of ACI 318 (and 350) require reinforcement to be added to the sides of an opening equal to the interupted reinforcing. Our standard detail has always called for this reinforcing …

  5. CJP Beam Splice In-Place | Eng-Tips

    Aug 31, 2017 · This has been a learning experience for me as it never even occurred to me that you could do overhead penetration welding. I guess it's not so different from multiple pass over head fillet …

  6. Fillet weld full penetration for plate in vibration fatigue?

    Jan 26, 2004 · Assuming that your design is new, I would suggest redesign using full penetration groove welds with reinforcing fillets. As metengr has so rightly stated, fillet weld designs are notoriously poor …

  7. Liquid CO2 Pumping | Eng-Tips

    Jul 9, 2003 · G'day all, I have a problem with a liquid CO2 pump failing every 4 to 9 months. The CO2 is at its boiling point ~-22°C at a pressure of ~1750kPag. The pump has 2 metres of liquid height above …

  8. welding / pre-qualified joints TC-U4a vs TC-U4b | Eng-Tips

    Jul 29, 2005 · Pre-qualified joints TC-U4a vs TC-U4b TC-U4a no root face; has backing bar TC-U4b has root face; no backing bar Question 1: For the TC-U4b, the shop drawings give the root face as 1/8”. …

  9. Reinforcement of SOD MEP Penetration | Eng-Tips

    Mar 30, 2021 · I recently came across a detail for a project a principal in my office is pier reviewing that calls for two #4 bars at all sides of an MEP opening in slab on deck. Rebar is to extend 3’ past the …

  10. CBR test - no reading at 0.2" penetration | Eng-Tips

    Oct 13, 2011 · The test standard requires penetration to 0.2 inches and if the CBR at 0.2 in penetration is greater than the CBR at 0.1 in penetration the test shall be rerun. I think what this means is you …